Measuring amplifier and signal converters

MESSOTRON produces the carrier frequency measuring amplifiers and signal converters required for operation of the LVDT / LVIT and other sensors and offers numerous variants, configurations and customized designs.

Type
Construction / Installation
Supply
MBI 46.51. field housing

MBI 46.51. field housing

  • Universal CF amplifier for LVDT / LVIT
  • Supply voltage: +24 VDC (10...36 VDC)
  • Carrier frequency: 5 kHz (or 10kHz / 20kHz)
  • Output signal: +0...10 V and 4 ... 20 mA
  • Cast housing IP 66 with cable gland
  • Wide range of adjustments
  • For harsh industrial environments
MBI 46.31. field housing

MBI 46.31. field housing

  • Supply voltage: +24 VDC / +230 VAC
  • Carrier frequency: 5 kHz (others optional)
  • Output signal: +10 V / 4 ... 20 mA
  • Type: Cast housing with cable gland
MBI 46.31. euroboard

MBI 46.31. euroboard

  • Supply: +24 VDC / +230 VAC
  • Frequency: 5 kHz
  • Output signal: +10 V / 4 ... 20 mA
  • Type: EU card / EU card, front panel / EU card, terminal block
MBI 46.32

MBI 46.32

  • Supply: ±15 VDC oder 24VDC
  • Carrier frequency: 5 kHz / others optional
  • Output signal: ±10 V or 4...20mA
  • Design: Plastic casing, top-hat rail
MBI 46.32

MBI 46.32

  • Supply: +24 VDC
  • Frequency: 5 kHz
  • Output signal: 10 V
  • Casing: Top-hat rail plastic casing
MBI 46.33. field housing

MBI 46.33. field housing

  • Supply voltage: ±15 V or +24 V
  • Carrier frequency: 5 kHz (others optional)
  • Output signal: ±10 V or 4...20 mA
  • Construction: Die-cast housing IP65
MBI 46.41

MBI 46.41

  • Supply: 85 ... 250 VAC oder 11 ... 36 VDC
  • Frequency: 5 kHz
  • Input: 20 mA or 10 VDC
  • Output signal: ±10 V
  • Up to IP 65 protection (in casing)
MBI 50.25 field housing

MBI 50.25 field housing

  • Supply: 230 VAC
  • Carrier frequency: 10 kHz
  • Output signal: ±10 V or 4...20mA
  • Design: Die-cast field housing
MBI 50.25 euroboard

MBI 50.25 euroboard

  • Supply: ±15 VDC or 230VAC
  • Carrier frequency: 10 kHz
  • Output signal: ±10 V or 4 ...20mA
  • Design: Euroboard PCB with front panel
MBI 50.43

MBI 50.43

  • Supply: ±15 VDC
  • Frequency: 10 kHz
  • Output signal: ±10 V
  • Design: Eurocard PCB
Q.bloxx A106

Q.bloxx A106

  • Supply: +10 ... 30 VDC
  • Frequency: DC / 600 Hz/ 4.8 kHz
  • Output: ±10 V
  • Design: Top-hat rail
Calibration box MVK

Calibration box MVK

  • Different sensitivity ranges selectable
  • Robust aluminium housing with selector switches
  • Electrical connection via 9-pin D-Sub plug
Converter MNHµCON

Converter MNHµCON

  • Supply: +24 VDC or -24 VDC
  • Design: Field housing 80 x 75 x 57 mm
  • Output signal: 0 ... 10 VDC or 0(4) ... 20mA
  • Dynamic range: 0 ... 10 kHz (-3 dB)
RD-Module

RD-Module

  • Compact top-hat rail module
  • Measuring range 1 ... 35mm
  • Supply voltage 18...30 VDC
  • Output signal 4...20 mA
LS-Module

LS-Module

  • Measuring range 10...100mV/mm/s at 10 ... 1000Hz
  • Supply voltage 18...30 VDC
  • Output signal 4...20 mA
  • Decoupled raw signal output for verification
  • Integrated sensor / self-monitoring
WS-Module

WS-Module

  • Peak value evaluation (0-P/P-P)
  • Measuring range -4...-20mV / 1 ... 1000µm
  • Supply voltage 18...30 VDC
  • Output signal 4...20 mA
Smax-Modul (SP) Wellenschwing. 2-Achsen

Smax-Modul (SP) Wellenschwing. 2-Achsen

  • Messumformer zur vektoriellen Auswertung von 2-achsigen Wellenschwingungen mittels Wirbelstromsensoren
  • kompaktes Rastschienenmodul
  • Messbereich 1 ... 1000 µm
  • Frequenzbereich 10 ... 1000 Hz
  • Versorgungsspannung 18...30 VDC
  • Ausgangsignal RSM/Sp-Sp 4...20 mA
  • Rohsignalausgang zur Überprüfung
  • Alarmfunktion obere/untere Schwellwerte
MBI 46.12 small module

MBI 46.12 small module

  • Supply: +24 VDC
  • Frequency: 5 kHz
  • Output signal: +10 V
  • Design: Small casing / Clamping block
MBI 46.13 cable module

MBI 46.13 cable module

  • Supply: +24 VDC
  • Frequency: 5 kHz
  • Output signal: +10V
  • Casing: Small casing