CF measuring amplifier MBI 46.33.
2-channel measuring amplifier for operation of inductive transducers / LVDT sensors
- Suitable for LVDT and LVIT
- Synchronized 2-channel version
- Rugged industrial metal housing IP 65
- In-channel zero and sensitivity adjustment
Important features
- Supply voltage: ±15 V or +24 V
- Carrier frequency: 5 kHz (others optional)
- Output signal: ±10 V or 4...20 mA
- Construction: Die-cast housing IP65
Suitable sensors
Type | Inductive transducers in differential LVIT sensor or differential transformer circuits | |
Required sensitivity | 20 ... 600 mV/V |
Oscillator (synchronized for both channels if necessary)
Carrier frequency | 5 kHz ±5% (sine); others optional | |||||
Bridge supply voltage |
approx. 2 Vrms
|
|||||
Supply current max. |
12 mArms
|
Amplifier (per channel)
Linearity |
< 0,1 % F.S.O.
|
|||||
Temperature coefficient of zero | < 0.1 % / 10 K at 100 mV/V transducer sensitivity < 0.15 % / 10 K at 20 mV/V transducer sensitivity |
|||||
Temperature coefficient of sensitivity | < 0.05 % / 10K at 100 mV/V transducer sensitivity < 0.15 % / 10 K at 20 mV/V transducer sensitivity |
|||||
Interference voltage (residual carrier voltage) |
< 5 mVrms
|
|||||
Input resistance |
approx. 200 kΩ
|
|||||
Output current max. |
6 mA
|
|||||
Zero offset | approx. ±10 % of the nominal range by trimming potentiometer up to 100 % of the nominal range by fixed resistor |
|||||
Zero point adjustment | through trim potentiometer | |||||
Gain adjustment | fine: by trimming potentiometer coarse: by fixed resistor |
|||||
Phase adjustment (may be omitted with matched measuring amplifiers) | fine: by trimming potentiometer coarse: by fixed capacitor |
|||||
Cut-off frequency for the measuring signal (-3 dB) |
500 Hz
|
General information
Power consumption max. | 2 W per channel at ±15 V or +24 V excitation | |||||
Electrical connection | Terminal blocks | |||||
Operating temperature | 0 ... 60°C | |||||
Storage temperature | -25 ... 85°C | |||||
Protection (DIN 40050) | IP 65 casing |
Type-dependent information
Supply (depending on option) | +20 ... +30 VDC / ±15 VDC stabilised max. 20 mVrms residual ripple 230 VAC |
|||||
Nominal output | ±10 V; 4 ... 20 mA | |||||
Dimensions W x H x L | approx. 120 mm x 91 mm x 220 mm | |||||
Weight | approx. 2,2 kg |
Model list
Product code | Channels | Casing | Supply | Output signal |
MBI 46.33.17 | 2-channel | Field housing | ±15 VDC | ±10 V |
MBI 46.33.18 | 2-channel | Field housing | ±15 VDC | 4 ... 20 mA |
MBI 46.33.27 | 2-channel | Field housing | 230 V | ±10 V |
MBI 46.33.27 | 2-channel | Field housing | 230 V | 4 ... 20 mA |
MBI 46.33.37 | 2-channel | Field housing | +24 V | ±10 V |
MBI 46.33.38 | 2-channel | Field housing | +24 V | 4 ... 20 mA |
Note:
The 10 V output provides a nominal output signal of ±10 V for balanced LVDT / LVIT. With unbalanced systems, e.g. MESSOTRON series WP, the output is 0 ... 10 V. This signal can be converted according to customer requirements.
Do you have further technical questions about the product?
We will be happy to help you determine the order code and provide you with further specific information for your required product.