WS-Module
Analogue single-channel measuring amplifier / evaluation board for measuring relative shaft vibrations with eddy current sensors
- Compact top-hat rail module
- Peak value evaluation (0-P/P-P)
- Measuring range -4...-20mV / 1 ... 1000µm
- Supply voltage 18...30 VDC
- Output signal 4...20 mA
- Decoupled raw signal output for verification
- Integrated sensor power supply
- Integrated sensor / self-monitoring
Technical data
Measuring range | -4...-20mV / 1...1000µm | ||||
Suitable sensors / measuring chains | Eddy current sensors with signal converter | ||||
Type of evaluation | Peak rectification (0-P / P-P) | ||||
Supply voltage WS module | 18 ... 36 VDC | ||||
Current consumption WS module | max. 130 mA | ||||
Power supply signal converter / measuring chain | -24VDC / 35mA | ||||
Measuring range setting | by fixed resistor | ||||
Tape fit adjustment | by fixed equipment | ||||
Default setting | Uin: -4...-20VDC / 0...250mm / Iout 4...20mA | ||||
Measuring circuit monitoring | Power failure / signal error | ||||
Output signal in case of error | 0mA / green LED goes out | ||||
Hold time error signal (0mA) | 20 seconds | ||||
Material module housing | Polycarbonate | ||||
Protection (DIN 40050) | IP 20 | ||||
Permissible operating temperature | -20 ... +70 °C | ||||
Electrical connection according to UL standard | AWG/kcmil: 30-12 | ||||
Clamps for wire cross-section | 0,2 up to 1 mm2 |
Do you have further technical questions about the product?
We will be happy to help you determine the order code and provide you with further specific information for your required product.
Circuit diagram and function
Signal processing
The output signal of the sensor is divided into three function paths at the signal input:Signal conditioning
Decoupling for the analysis output
Measuring circuit monitoring
In signal conditioning, the AC signal is normalised to the measuring range, passed through a bandpass filter and rectified in the peak value rectifier. The signal is converted into a standard current signal and output as a 4...20 mA signal.
At the test output, the sensor signal is available unfiltered and decoupled for measuring and analysis purposes.
The measuring circuit monitoring detects a sensor defect as well as a power failure. In the event of a fault, the current output is switched to 0 mA and the green LED goes out.
Dimensional drawings
Compact design
Housing dimensions approx. 90 x 62 x 2TE