LVDT sensor DPF
Pressure resistant valve displacement transducer with special flange and external sensor housing. The displacement transducer is Pressure resistant up to 320bar as standard and has a coil unit completely encapsulated in the casing with fully symmetrical coil construction according to LVDT full bridge circuit. Special versions with modified flange and installation dimensions, with integrated or external electronics, as well as in other pressure classes according to customer requirements are possible.
Important features
- Nominal stroke: 16mm (other options possible)
- Installation length: 74 mm (other options possible)
- Case diameter: 14mm (other options possible)
- Output signal: 0...V / 4 ... 20 mA
- Output signal PWM: <0.4 VDC to >4.6 VDC
- Operating temperature: 0 °C bis +80 °C
-
Protection class (DIN 40050): IP 65
Technical data
DPF 16 KTB A/P | |
Nominal stroke | ± 8 mm (total 16 mm) |
Mechanical stroke (min.) | 17 mm |
Dimension A | For valve NG12: 12.5 For valve NG18: 24.5 |
Dimension B (length without cable) | 74 ± 2 mm |
Sensor weight (approx.) | approx. 80 g |
Core rod weight (approx.) | approx. 4 g |
Non-linearity (typ.) | ± 2,0% of nominal stroke |
Case material | stainless steel |
Operating pressure | < 50 bar |
Operating temperature | 0°C bis +80°C |
Protection class (DIN 40050) | IP 65 |
Connection | PTFE cable, 5-wires, 0,2m, open braids |
Technical data - MBI 47.02
|
MBI 47.02 | |
Dimensions | mm | 83 x 30 (L x B) |
Weight | g | ca. 15 |
Operating voltage UB | VDC | 10 (15) - 30 |
Current consumption IB | mA | 40 |
Output (for nominal stroke) | Version A: 4 mA bis 20 mA Version P: PWM (< 0,4 VDC bis >4,6 VDC) |
|
Output load RL | Ohm | <300 (UB = 10 ... 30 VDC) <400 (UB = 12 ... 30 VDC) <500 (UB = 15 ... 30 VDC) |
Output variation. | IA = f (UB) IA = f (RL) |
typ. 50 µA / VB typ. 2 µA / Ohm |
Temperature coeff. of current output signal | ± 0,50% / 10K (incl. Sensor) | |
Connection | To sensor: 6-pin terminal Supply / output: soldering pads |
|
Operating temperature | 0° C ... +80° C | |
Protection class (DIN 40050) | IP20 |
Do you have further technical questions about the product?