LVDT sensor DPO
Pressure resistant cylinder displacement transducer with hole flange for installation in the cylinder base with internal sensor and core rod. The displacement transducer with a Case diameter of 20mm is Pressure resistant up to 320bar as standard and has a coil unit completely encapsulated in the casing with a fully symmetrical coil design according to the LVDT full bridge circuit. This achieves good linearity and high temperature stability with low temperature drift. Versions with 5kHz and 10kHz carrier frequency as well as for increased temperature are available.
Special versions with modified flange dimensions, with integrated electronics and in other pressure classes according to customer requirements are possible.
Special versions with modified flange dimensions, with integrated electronics and in other pressure classes according to customer requirements are possible.
Important features
- Nominal stroke: 25 mm to 1000 mm
- Pressure resistance: 320 bar as standard
- Case diameter: 20 mm
- Symmetrical full bridge circuit LVDT
- Connections: Radial cable, radial connector, axial connector
- Operating temperature: -40 ... 80 °C (option: up to 120 °C)
- Protection class (DIN 40050): IP 64
Technical data
DPO 25 |
DPO 50 |
DPO 100 |
DPO 150 |
DPO 200 |
DPO 250 |
DPO 300 |
DPO 400 |
DPO 500 |
DPO 600 |
DPO 800 |
DPO 1000 |
||
Nominal stroke | mm | ±12,5 | ±25 | ±50 | ±75 | ±100 | ±125 | ±150 | ±200 | ±250 | ±300 | ±400 | ±500 |
Max. mechanical stroke | mm | 30 | 55 | 105 | 160 | 210 | 260 | 320 | 420 | 520 | 630 | 830 | 1030 |
Dimension A | mm | 40 | 55 | 80 | 105 | 130 | 155 | 180 | 230 | 280 | 340 | 440 | 540 |
Mounting length B | mm | 60 | 100 | 140 | 220 | 300 | 380 | 480 | 600 | 730 | 860 | 1120 | 1400 |
Transducer weight (approx.) | g | 800 | 850 | 900 | 1000 | 1150 | 1250 | 1400 | 1600 | 1800 | 2000 | 2400 | 2800 |
Plunger weight (approx.) | g | 12 | 14 | 16 | 20 | 25 | 28 | 30 | 35 | 40 | 50 | 65 | 80 |
Carrier frequency* | 5 kHz, option: 10 kHz | 5 kHz | |||||||||||
Output signal (5 kHz) (approx.) |
mV/V | 100 | 110 | 140 | 125 | 130 | 135 | 140 | 150 | 160 | 175 | 175 | 175 |
Output signal (10 kHz) (approx.) |
mV/V | 100 | 100 | 135 | 140 | 140 | 160 | 210 | 210 | 250 | -- | -- | -- |
* Select option when ordering
Properties
DPO 25 ... 1000 | |||||||
Recommended measuring amplifier | MBI 46.31 | ||||||
Excitation voltage (eff.) | 1 ... 5 V | ||||||
Linearity error* | ±0,5 % F.S.O. option: ±0,25 % |
||||||
Temperature coefficient of zero | ±0,04 % / 10 K | ||||||
Temperature coefficient of span | ±0,1 % / 10 K | ||||||
Pressure resistance | operating pressure 320 bar, test pressure 450 bar | ||||||
Operating temperature* | -40 °C ... +80 °C, option: bis 120 °C | ||||||
Protection class (DIN 40050) | IP 64 |
* Select option when ordering
Do you have further technical questions about the product?
We will be happy to help you determine the order code and provide you with further specific information for your required product.
Dimensional drawings / Connection variants
DPO

Radial wire interface
Teflon cable 2.5m long


Radial connector interface
Mating connector supplied


Axial connector interface
Mating connector supplied