LVDT sensor DPU
Pressure resistant cylinder displacement transducer with hole flange for installation in the cylinder base with internal sensor and core rod. The displacement transducer with a case diameter of 18mm is pressure resistant up to 200bar as standard and has a coil unit completely encapsulated in the casing with a fully symmetrical coil design according to the LVDT full bridge circuit. This achieves good linearity and high temperature stability with low temperature drift. Versions are available for 5kHz and 10kHz carrier frequency as well as for increased temperature.
Special versions with modified flange dimensions and integrated electronics according to customer specifications are possible.
Special versions with modified flange dimensions and integrated electronics according to customer specifications are possible.
Important features
- Nominal stroke: 25 mm up to 1000 mm
- Pressure resistance: 200 bar
- Case diameter: 18 mm
- Symmetrical full bridge connection LVDT
- Connections: Radial cable, radial connector, axial connector
- Operating temperature: -40 ... 80 °C (option: up to 120 °C)
- Protection class (DIN 40050): IP 64
Technical data
DPU 25 |
DPU 50 |
DPU 100 |
DPU 150 |
DPU 200 |
DPU 250 |
DPU 300 |
DPU 400 |
DPU 500 |
DPU 600 |
DPU 800 |
DPU 1000 |
||
Nominal stroke | mm | ±12,5 | ±25 | ±50 | ±75 | ±100 | ±125 | ±150 | ±200 | ±250 | ±300 | ±400 | ±500 |
Max. mechanical stroke | mm | 30 | 55 | 105 | 160 | 210 | 260 | 320 | 420 | 520 | 630 | 830 | 1030 |
Dimension A | mm | 40 | 55 | 80 | 105 | 130 | 155 | 180 | 230 | 280 | 340 | 440 | 540 |
Mounting length B | mm | 60 | 100 | 140 | 220 | 300 | 380 | 480 | 600 | 730 | 860 | 1120 | 1400 |
Transducer weight (approx.) | g | 950 | 1000 | 1050 | 1150 | 1300 | 1400 | 1550 | 1750 | 1900 | 2100 | 2500 | 2900 |
Plunger weight (approx.) | g | 12 | 14 | 16 | 20 | 25 | 28 | 30 | 35 | 40 | 50 | 65 | 80 |
Carrier frequency* | 5 kHz, option: 10 kHz | 5 kHz | |||||||||||
Output signal (5 kHz) (approx.) |
mV/V | 100 | 110 | 140 | 125 | 130 | 135 | 140 | 150 | 160 | 175 | 175 | 175 |
Output signal (10 kHz) (approx.) |
mV/V | 100 | 100 | 135 | 140 | 140 | 160 | 210 | 210 | 250 | -- | -- | -- |
* Select option when ordering
Properties
DPU 25 ... 1000 | |||||||
Recommended measuring amplifier | MBI 46.31 | ||||||
Excitation voltage (eff.) | bis 5 V | ||||||
Linearity error* | ±0,5 % F.S.O. Option: ±0,25 % |
||||||
Temperature coefficient of zero | ±0,04 % / 10 K | ||||||
Temperature coefficient of span | ±0,1 % / 10 K | ||||||
Pressure resistance | operating pressure 200 bar, test pressure 300 bar | ||||||
Operating temperature* | -40 °C ... +80 °C, option: up to 120 °C | ||||||
Protection class (DIN 40050) | IP 64 |
* Select option when ordering
Do you have further technical questions about the product?
We will be happy to help you determine the order code and provide you with further specific information for your required product.
Dimensional drawings / Connection variants
DPU
Radial wire interface
Teflon cable 2.5m long
Radial connector interface
Mating connector supplied
Axial connector interface
Mating connector supplied