LVDT sensor DUR
Inductive LVDT sensors differential transformer version - special version
- Measuring range 25 … 1000 mm
- 14 mm diameter
- with cable axial
Important features
- Nominal stroke: 25 mm up to 1000 mm
- Installation length: 80 mm up to 1420 mm
- Case diameter: 14 mm
- Operating temperature: -40 °C to +80 °C (option: up to 120 °C)
-
IP 64
Technical data
DUR 25 |
DUR 50 |
DUR 100 |
DUR 150 |
DUR 200 |
DUR 250 |
DUR 300 |
DUR 400 |
DUR 500 |
DUR 600 |
DUR 800 |
DUR 1000 |
||
Nominal stroke | mm | ±12,5 | ±25 | ±50 | ±75 | ±100 | ±125 | ±150 | ±200 | ±250 | ±300 | ±400 | ±500 |
Mechanical stroke | mm | 28 | 55 | 105 | 160 | 210 | 260 | 320 | 420 | 520 | 630 | 830 | 1030 |
Dimension A | mm | 40 | 55 | 80 | 105 | 130 | 155 | 180 | 230 | 280 | 340 | 440 | 540 |
Installation length B | mm | 80 | 120 | 160 | 240 | 320 | 400 | 480 | 620 | 750 | 880 | 1140 | 1420 |
Sensor weight (approx.) | g | 440 | 470 | 500 | 550 | 600 | 650 | 700 | 770 | 850 | 920 | 1100 | 1200 |
Core weight (approx.) | g | 7 | 9 | 12 | 20 | 25 | 28 | 30 | 35 | 40 | 50 | 65 | 80 |
Nominal output signal (5 kHz) (approx.) |
mV/V | 100 | 110 | 140 | 125 | 130 | 135 | 140 | 150 | 160 | 175 | 175 | 175 |
Properties
DUR 25 ... 1000 | |
Carrier frequency
|
5 kHz |
Recommended measuring amplifier
|
MBI 50.33 |
Supply voltage (rms) | up to 5 V |
Linerarity | ±0,25 % F.S.O. |
Temperature coefficient of zero | ±0,04 % / 10 K |
Temperature error of sensitivity | ± 0,1 % / 10 K |
Operating temperature* | -40 ° C ... +80 ° C, Option: up to 120 °C |
Protection class according to DIN 40050 | IP 64 |
* Specify options on order
Do you have further technical questions about the product?
We will be happy to help you determine the order code and provide you with further specific information for your required product.
Dimensional drawings
DUR

Radial connector
Teflon cable 150 mm long,
assembled with 6-pole Molex connector
Core channel not continuous