LVDT sensor WLU
Special design displacement transducer for safety and hydraulic valves in the power plant sector. The LVDT sensor with a Case diameter of 16 mm has a coil unit with a fully symmetrical coil design according to the LVIT differential choke principle in a half-bridge circuit. The design guarantees high temperature stability with very low temperature drift.
Important features
- Nominal stroke: 100 mm up to 300 mm
- Mechanical stroke: 55 mm up to 185 mm
- Case diameter: 16 mm
- Operating temperature: -50 ... 120 °C, briefly up to 150 °C
- Protection class (DIN 40050): IP 65
Technical data
WLU 100 |
WLU 150 |
WLU 200 |
WLU 300 |
WLU 350 |
||
Nominal stroke | mm | ±50 | ±75 | ±100 | ±150 | ±175 |
Maximum stroke | mm | ±55 | ±82,5 | ±110 | ±158 1 | ±185 1 |
Dimension A | mm ±1 | 85 | 110 | 135 | 185 | 210 |
Dimension B | mm ±1 | 245 | 355 | 455 | 675 | 780 |
Transducer weight (approx.) | g | 380 | 480 | 580 | 780 | 880 |
Core weight (approx.) | g | 60 | 76 | 93 | 130 | 150 |
Nominal output | mV/V ± 10 % | 314 | 325 | 340 | 322 | 322 |
Sensitivity | mV/V/mm ± 10 % | 6,3 | 4,33 | 3,4 | 2,15 | 1,84 |
1 limited by required dimension A
Equal product data
WLU 100 ... 350 |
||||||
Impedance (coil with core inserted) | (±100) 600 Ohm | |||||
Excitation (eff.) | max. 22 V | |||||
Carrier frequency | 3 kHz | |||||
Linearity over nominal stroke | max. ±1,0 % F.S.O. | |||||
Linearity over maximum stroke | max. ±1,5 % F.S.O. | |||||
Operating temperature | -50 °C ... 120 °C, briefly up to 150 °C | |||||
Protection class (DIN 40050) | IP 65 |
Do you have further technical questions about the product?
We will be happy to help you determine the order code and provide you with further specific information for your required product.
Dimensional drawings / Connection variants
WLU

Radial connector
Connector:
Amphenol C091 31W003 100 2 or compatible
Mating connector:
Amphenol C091 31D003 100 2 or compatible, fitted with 2 m shielded Teflon-cable