LVDT sensor WLU

Special design displacement transducer for safety and hydraulic valves in the power plant sector. The LVDT sensor with a Case diameter of 16 mm has a coil unit with a fully symmetrical coil design according to the LVIT differential choke principle in a half-bridge circuit. The design guarantees high temperature stability with very low temperature drift.

Important features

  • Nominal stroke: 100 mm up to 300 mm
  • Mechanical stroke: 55 mm up to 185 mm
  • Case diameter: 16 mm
  • Operating temperature: -50 ... 120 °C, briefly up to 150 °C
  • Protection class (DIN 40050): IP 65

Technical data

    WLU 100
WLU 150
WLU 200
WLU 300
WLU 350
Nominal stroke mm ±50 ±75 ±100 ±150 ±175
Maximum stroke mm ±55 ±82,5 ±110 ±158 1 ±185 1
Dimension A mm ±1 85 110 135 185 210
Dimension B mm ±1 245 355 455 675 780
Transducer weight (approx.) g 380 480 580 780 880
Core weight (approx.) g 60 76 93 130 150
Nominal output mV/V ± 10 % 314 325 340 322 322
Sensitivity mV/V/mm ± 10 % 6,3 4,33 3,4 2,15 1,84
1 limited by required dimension A

Equal product data

  WLU 100 ... 350
Impedance (coil with core inserted) (±100) 600 Ohm
Excitation (eff.) max. 22 V
Carrier frequency 3 kHz
Linearity over nominal stroke max. ±1,0 % F.S.O.
Linearity over maximum stroke max. ±1,5 % F.S.O.
Operating temperature -50 °C ... 120 °C, briefly up to 150 °C
Protection class (DIN 40050) IP 65

Dimensional drawings / Connection variants

WLU

dimensional drawing wlu

Radial connector

Connector:
Amphenol C091 31W003 100 2 or compatible

Mating connector:
Amphenol C091 31D003 100 2 or compatible, fitted with 2 m shielded Teflon-cable

connection wlu

Downloads

icon-pdf-blueProduct data sheet

icon-pdf-blueInstallation / technical information

icon-pdf-blueProduct group overview

Accessories

teaser image electronics and measuring amplifiers

Measuring amplifiers

View products

teaser image calibrators

Calibrators

View products

teaser image accessories

Accessories

View products