Eddy current sensors with integrated electronics

The compact MNS proximity sensors with integrated conversion electronics are used for measurements under normal ambient temperatures (<70°C). They are particularly suited for acquisition of static gaps up to 15 mm and slow movements.

The measuring behavior of the MNS eddy current sensors is specified for objects to be measured with a large, smoothly-formed surface of steel (ST37). The analog measurement values are provided as current signals or voltage signals, depending on the version of the sensors.

Tabular overview of the MNS eddy current sensors.

 

MNS2-G6,5

  • Measuring range 0.5 to 2 mm
  • housing for flush mount, IP67
  • only 6.5 mm diameter
  • Power supply 11…35 VDC
  • Output 0…10 V
  • with cable connection

MNS2-M8

  • Measuring range 0.5 to 2 mm
  • compact M8 housing, IP67
  • for flush mounting
  • Power supply 11…35 VDC
  • Output 0…10 VDC
  • with cable connection or M8 sensor plug

MNS3-M12

  • Measuring range 0.25 to 3 mm
  • M12 housing for flush mount, IP67
  • Power supply 11…35 VDC
  • with cable connection or M12 plug
  • Output 1...9 VDC or 4...20 mA

Optional:

  • non-flush mounting (working area 0.5 to 4 mm)

MNS5-M18

  • Measuring range 0.5 to 5 mm
  • M18 housing for flush mount, IP67
  • Power supply 11…35 VDC
  • with cable connection or M12 plug
  • Output 1...9 VDC or 4...20 mA

Optional:

  • non-flush mounting (working area 1 to 8 mm)

MNS12-M30-NB

  • Measuring range 3 to 15 mm
  • M30 housing, IP67, for non-flush mounting
  • Power supply 11…35 VDC
  • with cable connection or M12 sensor plug
  • Output 1…9 VDC or 4...20 mA

Optional:

  • current and voltage output
  • additional 4-bit digital output
  • flush mount (working area 1 to 9 mm)

Cookies help us in providing our services. By using our services, you agree that we use cookies. Further information

OK