CF-measuring amplifier MBI 46.31.
Standard measuring amplifier in field housing for operation of inductive LVDT sensors
- Suitable for LVDT and LVIT
- Rugged field housing IP65
- Adjustable gain, zero offset and phase adjustment
- Fine adjustment possible on site via potentiometer
Important features
- Supply voltage: +24 VDC / +230 VAC
- Carrier frequency: 5 kHz (others optional)
- Output signal: +10 V / 4 ... 20 mA
- Type: Cast housing with cable gland
Technical data
| Linearity | < 0,1 % FSO | |
| Carrier frequency | 5 kHz ±5 % (sine); optional: 1 ... 20 kHz | |
| Dynamic range | 500 Hz (±3 dB); (max. 1/10 of carrier frequency) | |
| Supply voltage (primary) | approx. 2 Vrms at 5 kHz, sinusoidal; max. 12 mArms | |
| Input resistance (secondary) | approx. 200 kΩ | |
| Output signal | 4 ... 20 mA, load < 500 Ω or ±10 VDC, load resistance > 10 kΩ | |
| Noise level and residual carrier voltage | < 5 mVrms | |
| Temperature coefficient of zero-value | < 0,10 % / 10 K at 100 mV/V < 0,15 % / 10 K at 20 mV/V |
|
| Temperature coefficient of gain | < 0,05 % / 10 K at 100 mV/V < 0,15 % / 10 K at 20 mV/V |
|
| Operating temperature | 0 ... 60 °C | |
| Storage temperature | -25 ... 85 °C | |
| Electromagnetic compatibility | DIN EN 61326-1 | |
| Electrical safety | DIN EN 61010-1 |
Field housing ±15 V or 24 V
| Supply voltage | MBI 46.31.1y: ±15 VDC stabilized, resp. MBI 46.31.3y: +20 ... +36 VDC |
|||||
| Power consumption |
max. 2 W
|
|||||
| Electrical connection | Terminal block (internal), connection cable for supply voltage, LVDT sensor and output signal led out |
|||||
| Dimension | approx. W 120 x H 91 x D 122 mm | |||||
| Weight |
approx. 1,4 kg
|
|||||
| Protection (DIN 40050) |
IP 65
|
|||||
Field housing 230 VAC (115 VAC)
| Supply voltage |
230 VAC (±10 %), 48 ... 60 Hz (115 VAC)
|
|||||
| Power consumption |
max. 4 W
|
|||||
| Electrical connection | Terminal block (internal), connection cable for Supply voltage (with Schuko plug), LVDT sensor and output signal led out |
|||||
| Dimension W x H x D |
approx. 120 x 91 x 220 mm
|
|||||
| Weight |
approx. 2 kg
|
|||||
| Protection (DIN 40050) |
IP 65
|
|||||
Suitable sensors
| Inductive differential transformers (LVDTs) | in 4-wire technology | |||||
| Differential choke (LVITs) and long travel transducers (eddy current technology) | Inductive half bridges with 3-wire technology | |||||
| Rated output |
20 ... 600 mV/V
|
|||||
| Input impedance |
100 ... 1000 Ω
|
|||||
Model list
| Product code | Design | Supply | Output ignal |
| MBI 46.31.17 | Field housing | ±15 VDC | ±10 V |
| MBI 46.31.18 | Field housing | ±15 VDC | 4 ... 20 mA |
| MBI 46.31.27 | Field housing | 230 VAC | ±10 V |
| MBI 46.31.28 | Field housing | 230 VAC | 4 ... 20 mA |
| MBI 46.31.37 | Field housing | +24 VDC | ±10 V |
| MBI 46.31.38 | Field housing | +24 VDC | 4 ... 20 mA |
| MBI 46.31.... | Euroboard versions |
| Options | Order code |
| other carrier frequencies in the range 1 ... 20 kHz | /... kHz |
| Output signal 0 ... 10 V | /0-10 V |
| Output signal 0 ... 20 mA | /0-20mA |
| Supply instead of 230V, only available in field housing | /115 V |
Do you have further technical questions about the product?
We will be happy to help you determine the order code and provide you with further specific information for your required product.